Mechanism of “Mimalog Cloud”

Mechanism(Room)

『Installation for wireless sensor in room』

shikumi

※1:Recorded in Blue Ocean System

Room Target Monitor Alarm Cooperate with BOS ※1
Opening-closing Sensor Entrance door 〇:Entering and leaving
Human Sensor Toilet 〇:Using for toilet
Vital Sensor(heartbeat) Bed 〇:Average / abnormal
Vital Sensor(breathing) Bed 〇:Average / abnormal
Vital Sensor(Human) Bed 〇:Leaving and going to bed
Room 〇:In room

Mechanism(common area)

『Installation for wireless sensor in common area』

1st floor Target Monitor Alarm Cooperate with BOS ※1
Human Sensor Toilet 1 near to service entrance
Toilet 2 near to service entrance
Toilet in front of the office
Temperature and Humidity Sensor Corridor in waiting room of clinic
Near the hall・cognibike
Washroom of service entrance
Dressing room of bathroom
2nd floor, 3rd floor, 4th floor Target Monitor Alarm Cooperate with BOS ※1
Human Sensor Dressing room of bathroom
Dining room(hall)
Temperature and Humidity Sensor North:NorthSide Corridor 〇:Average / abnormal
east:Corridor near to dining room(hall) 〇:Average / abnormal
south:West side of SouthSide Corridor 〇:Average / abnormal
West:Westside Corridor of staff room 〇:Average / abnormal

※1:Recorded in Blue Ocean System

“Mimalog Cloud”

Summary

『The role of function (in each view)』

View name Target Display content Usage purpose Until it is displayed
Monitoring View(floor) Every floor State in recent 30 minutes(Aggregate results) Even if it is checked occasionally, state can be known by log It will take a little time(1 minute to aggregate)
Monitoring View(room) Every room State in recent 30 minutes(Aggregate results) Current state can be known It will take a little time(1 minute to aggregate)
Cosmic View Entire Realtime Even if it is checked occasionally, state can be known by log Immediately※a part of data is excluded
monitor_floor
monitor_room
cosmo

Monitoring View(floor)

『Aggregate results of each floor in recent 30 minutes is displayed』

minitor_floor1

『Monitoring panel』

mimarogu_panel

『Panel for displaying number of people who stays in room』

humanNumberPanel

『Common area temperature/Common area Humidity/Temperature・Humidity panel in bathroom』

shareTempreture

『System information panel』

systemPanel

『Alarm settings panel』

 alarm

Monitoring View(room)

『All rooms in every floor are displayed separately』
– The status reflects the situation in recent 30 minutes

monitorRoomOne

『The state and history of room are displayed』

monitorRoomTwo

『The display for each icon’s status is as follows.』

everyIconState

『Communication abnormality /Sensor abnormality』

monitorRoomFour

『Operation for vital abnormality』

monitorRoomFive

Cosmo View

『Real-time status of building or each floor is displayed』

cosmo3D

『Display of Cosmo View – room』

cosmoRoom

『Display of Cosmo View – common area/bathroom/dining room』

cosmoShare

Abnormality in the building and alarm

Type of abnormality and alarm

『Notifying by email when abnormality in the building is detected』
– Email notification
– Nurse call notification(2nd floor、3rd floor、4th floor)

Type of abnormality Monitoring target Alarm content Notification method
Temperature Corridor、bathroom・dressing room When temperature is over the normal range Mail
Humidity Corridor、bathroom・dressing room When humidity is over the normal range Mail
Vital Room When heartbeat, breathing and body motion of user is weak Mail
Nurse call
Using toilet for a long time Room When user stays in room’s toilet for a long time Mail

※It is possible to change the parameter setting of determining abnormality from setting page(only for manager)